July 20, 2014 at 7:13 pm #111804PriestunesParticipant
Hi there. Can someone tell me what I'm doing wrong when I send the H9 a CC message to turn ON the the Performance Switch (or FLEX in some presets) that it remains ON and can't seem to be turned OFF? From the GUI, I can operate the FLEX button one of two ways: briefly click the FLEX button and the FLEX function will toggle ON and OFF, or click and hold the mouse, which gets it to remain ON as long as the mouse is over the FLEX button. Once moved OFF, it disengages the FLEX. Either way, via MIDI, I can only seem to get it to turn ON, unless I bypass the algorithm entirely, which is not an acceptable solution (performance wise). Thanks!
-
July 21, 2014 at 1:38 pm #126368gkellumParticipant
I was just playing with triggering the Flex switch via MIDI CC; it turns on when the CC value is above 64 and turns off when the CC value is below 64.
-
July 21, 2014 at 1:55 pm #126369gkellumParticipant
After looking into the performance switch some more, the behavior seems to be inconsistent when its triggered by MIDI CC. With TimeFactor algorithms for instance it expects the MIDI CC value to be above 64 to turn it on AND off. We're going to have to look into this some more…
-
July 23, 2014 at 6:22 pm #137056PriestunesParticipant
Thanks for figuring this out. Nice job! (And sorry for the duplicate threads. I thought I'd take the liberty to start a very clearly stated thread for search purposes.)
-
July 24, 2014 at 6:38 pm #137065pauliusmmMember
I also got in to the same problem. Hope this will get fixed soon.
-
June 7, 2015 at 7:54 pm #139312dented42fordParticipant
This is apparently still an issue, as of early June 2015. How’s that “looking into” going?
-
October 17, 2015 at 8:19 pm #141125Alex_CheckmanParticipant
I would also like to control performance switch via midi to on/off from the same cc message. There is no place where I can specify off message and disaster area DMC sends one cc message (I am pretty sure any other midi controller only sends one message per button). Basically performance switch is unusable for me as h9 does not have buttons to control it either. Will there be any update to this?
-
October 18, 2015 at 8:43 am #141132spaceJamMember
I’m using a “Stomp” type of switch in the Liquid Foot Mini and I’m able to do this without any issue whatsoever.
I send a CC with value of 127 to turn the FLEX ON and then the same CC with value of 0 to turn it OFF.
H9 has 5.2.0[1] firmware version, if that helps.
-
-