H90 EXP/CTL input specifications

Home Forums Products Stompboxes H90 EXP/CTL input specifications

Viewing 2 reply threads
  • Author
    Posts
    • #168129
      fonitronik
      Participant

      I was not able to find the correct answer in the manual or here inthe forum.

      Assuming that the CTL inputs expect 0-5V. However, my SERGE modular can easily output control voltages of -12V to +12V.

      How are the H90 EXP/CTL inputs protected against over- (or under-) voltage? Are they at all?

    • #168188
      tbskoglund
      Moderator
      Eventide Staff

      That is correct, the H90 will respond in the range of 0-5V. It has adequate circuit protection to make standard synth ranges safe.

    • #168205
      fonitronik
      Participant

      By standard synth range you ean +12V/COM/-12V, I assume? That is good to know.

      The input impedance of these inputs is 100k?

      Thank you.

Viewing 2 reply threads