Hello,
My setup is as follows:
1) A RME multichannel audio interface running at 88.2 kHz and outputting a master wordclock signal to the H8000FW, and connected to it via AES3/4 (sync. OK).
2) A stereo Lexicon FX processor running at 44.1 kHz/16 bit and connected to H8000FW's SPDIF1/2 input/output (having sample rate conversion activated).
The H8000FW is running at the wordclock rate of RME, and due to the SRC feature is also in sync with the signal coming from Lexicon processor (if it's running an internal 44.1 kHz clock). However, shall I switch the Lexicon's clock to external (derived from the SPDIF input) and the Lexicon can't lock to the Eventide's master clock signal on SPDIF. Everything works fine if all units are using the same 44.1kHz clock (including the RME) and SRC is also disabled in H8000FW.
Is it possible to get my Lexicon lock to the H8000FW's SPDIF output under active sample rate conversion?