      Hello

      I need to recall bypass my TIMEFACTOR via "midi pedalboard"…

      I try to explane:

      I want a preset (ex 1:1) but trubypass (whitout any effect and direct in to out)!

      Is it possible?

      I set MY program change in this mood:

      CH1 – 1:1, CH2 – 1:2… ecc

      but I need a CHxx – BYPASS…

      (my MIDI Pedal Board is MIDIONE FLX-8)

      Sorry For my Englisch (…I'm from Italy)

      Thank You Very Much

      Nicola

    • #121085
      nickrose
      Moderator
      Eventide Staff

      Hi Nicola

      If I understand you, you want a relay bypass. So, after having carefully studied the User Manual

      1) set the [BYPASS][BYP TYP] to RLY.

      2) Assuming you want to use MIDI Program Change to select the bypass:

      edit the [MIDI][RCV MAP] to give you either OFF, ACT,TOG or BYP, depending on how you want to control it. These values are:

                     OFF   Unassigned

                      BYP    BYPass the unit

                      ACT    Make the unit Active, i.e. not bypassed.

      TOG   Toggle the between bypass and active.

    • #121120
      NickDeRossi
      Member

      Thanks for the help but …in my spompbox, into the menu [MIDI][RCV MAP], i can choose only the number of preset or OFF!!

       

      Its' very strange…

       

      I Try to explane: This is the situation:

       

      CHn° > N°preset or OFF (not BYP, ACT or TOG)

       

      EX:

       

      0 to 127 > OFF to 20:2

       

      I have to download new software??

      Nicola

    • #132268
      nickrose
      Moderator
      Eventide Staff

      You may have very old software which did not have this feature. Check the appropriate support page on the WebSite to see if there is an upgrade.