      Zaphod B
      Member

      I my two Eventide stomp boxes, TimeFactor and ModFactor list a power requirement of 9V / 1200 mA, and the power supply wall warts supplied with them are rated as such. (And the owner's guide cautions against using anything other than the supplied power supply.)

      However, the four Power Factor 2 outlets that are intended for Eventide boxes are only rated at 400mA.

      So my question is: Huh? Can someone please explain?

      Thanks!

    • #125231
      nickrose
      Moderator
      Eventide Staff

      The current rating was overstated on the TF/MF and PF (sorry) – a nominal 400mA is fine.

    • #125232
      Zaphod B
      Member

      Excellent, thanks!

    • #136103
      Zaphod B
      Member

      Nick – one additional question. 

      The nominal supply voltage for the Eventide stompboxes is 9V,  but two of the Powerfactor's 400mA outputs are 12V only. I read on CIOK's site that they recommend running Eventide stompboxes with 12V.

      What is Eventide's recommendation for stompbox supply voltage?

      Thanks!

    • #136105
      nickrose
      Moderator
      Eventide Staff

      A regulated 12V is OK.

      An unregulated supply (such as a transformer-based wallwart) should be rated at 9V, as it could be higher than this at times.

      More than about 15V (even for a short time) could cause damage to the internal circuitry.

      Note that any damage caused by the use of a non-Eventide power supply is not covered by the warranty, so best to play safe.

    • #136106
      Zaphod B
      Member

      But it's OK to use the 12V taps on the Powerfactor 2?

    • #136107
      nickrose
      Moderator
      Eventide Staff

      If he says to use the 12V outputs, he must have confidence in their regulation, so they should be OK.

    • #136108
      nickrose
      Moderator
      Eventide Staff

      In the interest of a more definitive answer, I measured a PowerFactor. The 12V outputs are within 0.25V of 12, so they are regulated and thus safe to use.

      Lord Poul probably recommends the 12V output as the 'Factors will take less current at the higher voltage.

    • #136109
      Zaphod B
      Member

      Got it; thanks again.