June 21, 2014 at 7:16 pm #111728aggiemike08Member
I'm using a fractal audio MFC-101 to control the timefactor.
I am able to get the PC commands to work but I cannot get any CC commands to work. I'm trying to control the effect bypass/active.
i have RCV Channel set to 1 and RCV CTL for the bypass set to CC0.
on the MFC-101 I am sending a CC 0 on channel 1 but the timefactor does not bypass or activate. Like I said when i send a PC command on channel 1 it works. Any ideas?
-
June 21, 2014 at 7:38 pm #126180aggiemike08Member
Also, I'm doing the same thing/strategy with the space pedal which is working but not on the timefactor
-
June 21, 2014 at 8:08 pm #126181brockParticipantQuote:on the MFC-101 I am sending a CC 0 on channel 1 but the timefactor does not bypass or activate. Like I said when i send a PC command on channel 1 it works. Any ideas?
It appears that you already have MIDI -> OUTPUT set to THRU (program changes are received).
I'm thinking that the problem lies with the value of the CC0 message that you're sending. A continuous controller message has two parts: CC number, and the value 0-127. In a "switching" type of situation, any value from 0-63 is OFF; 64-127 is ON.
As an example, I have my FCB 1010 send a CC number with a value of 127 for Bypass, and the next press of the footswitch sends the same CC number, but with a value of 0 (for Active).
-
June 21, 2014 at 10:39 pm #126183aggiemike08Member
I did not know that… I was trying to use 0 and 1. The MFC had 0 and 127 as default. Must have been why. Let me try that out
-
June 22, 2014 at 1:40 am #126184aggiemike08Member
Is the bypass state saved with the preset? I'm trying to get the instant axess switch to load a certain delay preset and activate it when I select the switch but then bypass when I bypass the instant axess switch. It seems the saved state is over rising the CC commands
-
June 23, 2014 at 4:28 pm #126200
When you load a preset with a PC, the bypass state is that when it was saved.
-
-