- Eventide Audio

Home Forums Products Rackmount any way for the h9000 to not say my system is running the wrong sample rate and muting itself? Reply To: any way for the h9000 to not say my system is running the wrong sample rate and muting itself?

#153018
taylor12k
Participant

yeah, i tried that.. going to 48 then back.. with and without pro tools open. 

the only thing i didn’t try was rebooting the entire computer… it was easier to shut off the 9000 and choose something else at that point..

hopefully i can get them to work together at some point.

 

jbamberg wrote:

It is a bit counter intuitive but you need to set the sample rate on the computer after you set it on the H9000.  If you get the mismatch warning, change the sample rate on the computer to 48 and then back to 44.1 again.  You shouldn’t need to restart the H9000.

This is a consequence of the H9000 using asynchronous USB audio.  Unfortunately there is no way for the H9000 to force the computer’s clock to re-sync when its sample rate changes.  The computer has to initiate this process.