H90 Cant PC and Bypass CC together. *BUG*

Home Forums Products Stompboxes H90 Cant PC and Bypass CC together. *BUG*

Viewing 3 reply threads
  • Author
    Posts
    • #185803
      lxm9096
      Participant

      MC6 PRO

       

      I can send a PC message of 50 for example and it loads

      I can send a CC of value = 0 “P ACT/BYP M” and it will deactivate. Send a value of 127 and it will activate.

      I cannot send both the above. It wont work. Even with a delay message in between from the morningstar controller. Am I missing something. I am pretty sure this is just a bug

    • #185804
      joecozzi
      Moderator
      Eventide Staff

      We are aware of this problem, but please report your request to support@eventideaudio.com so developers can better assess priorities. Thank you.

    • #185808
      lxm9096
      Participant

      Thank you. I have emailed support. I have tried everything I can think of here. Put the messages first in the chain. Delay to the max(1260ms) no changes.

    • #186006
      lxm9096
      Participant

      Thank you. I have emailed support. I have tried everything I can think of here. Put the messages first in the chain. Delay to the max(1260ms) no changes.

      I have been going back and fourth with support and they said

      “This is just how the MIDI was implemented on the H90, but it can be improved in the future”

      Not being able to load and change the bypass state of a patch is EXTREMELY basic behaviour for any pedal. Let alone the one I dropped over $1300 for. It’s broken… not implemented that way

Viewing 3 reply threads