      tavernier
      Participant

      Dear H90 forum,

      I’m encountering issues with a quite simple séquence I would like to do :

      “Switch to a specific program, then engage a HotSwich config”

      From a unit sequence point of view, quite easy : Send a PC message, then a CC configure to the appropriate HS

      Each Message is OK, but this does not work when I’m chaining the two message (maybe due to a lack of reactivity / buffering of H90 in midi). I’m using the latest firmware.

      Any idea of the issue ?

    • #186409
      brock
      Participant

      Not to discount the MIDI question (it’s come up before).  It’d be helpful to Eventide if you specified which MIDI controller you’re using.  And maybe even the current Tempo (if applicable) for delta time calculations.

      But what struck me here was an easy alternative:  You require a Program load – via PC message – immediately followed by a HotSwitch configuration.  Can’t you just re-save the Program with HS(x) = ON?  No delay; it’s now part of the initial Program load operation.

    • #186414
      tavernier
      Participant

      I’m using a MC6 Pro through the “DIN” interface.

      Thanks for you workaround which is unfortunately not easy with my conf (since it multiply by 3 numerous presets)